AC Config 1 Power Supply 1100W PWR-C1-1100WAC-P

1100W AC Config 1 Power Supply

600,00 AED

SKU PWR-C1-1100WAC Category
  • Sold By : Cloudshare Tech
  • Delivery Within 7 Working Days
Brands

Cisco

Warranty

6 Month

Condition

New Pulled

Cisco PWR-C1-1100WAC-P – 1100W AC Power Supply with Port-Side Exhaust Airflow for Catalyst & Nexus Switches

AC Config 1 Power Supply

The Cisco PWR-C1-1100WAC-P is a high-capacity, enterprise-grade 1100-watt AC power supply engineered for Cisco Catalyst 9000 and Nexus 9000 Series switches, including the Catalyst 9300, 9400, 9500, and Nexus 9300-EX/FX platforms. Designed with port-side exhaust (P) airflow, this power supply delivers reliable, redundant, and intelligent power management while aligning with specific data center cooling strategies that require hot air to be expelled through the front (port side) of the chassis.

Ideal for high-density, power-hungry deployments—such as those supporting PoE++ (up to 90W per port), high-speed optics, or modular uplinks—the PWR-C1-1100WAC-P ensures continuous operation in mission-critical environments, from enterprise cores to cloud-scale data centers.


Key Features & Specifications

  • Model: PWR-C1-1100WAC-P
  • Power Output: 1100W AC
  • Input Voltage: 100–240V AC (auto-ranging, 50/60 Hz)
  • Airflow Direction: Port-side exhaust (P) – hot air exhausted through the front (port side)
  • Compatibility:
    • Cisco Catalyst 9300, 9400, and 9500 Series (select models with high-wattage PSU support)
    • Cisco Nexus 9300-EX/FX Series (e.g., N9K-C93180YC-EX, N9K-C9336C-FX2)
  • Redundancy: Supports 1+1 or N+1 power redundancy
  • Hot-Swappable: Yes – enables replacement without service interruption
  • Efficiency: 80 PLUS Platinum certified for energy efficiency and lower operational costs
  • Intelligent Management: Fully monitored via Cisco IOS-XE or NX-OS (show power, show environment)
  • Cisco Certified: Validated for thermal, electrical, and mechanical integration

Note: The “-P” suffix denotes Port-side Exhaust airflow. Always ensure all system components (power supplies, fans) use matching airflow to prevent thermal issues.


Understanding Port-Side Exhaust (P) Airflow

In standard data center designs, front-to-back (port-side intake) is common—cool air enters the front, hot air exits the rear. However, some deployments (e.g., rear-door heat exchangers, back-to-back racks, or legacy layouts) require the reverse:

  • Port-side exhaust (P) means:
    • Cool air is drawn from the rear (power side)
    • Hot air is expelled through the front (port side)

This configuration is less common but critical in specific environments. Installing a P (exhaust) PSU in a system designed for I (intake) airflow—or vice versa—can cause:

  • Overheating
  • Thermal throttling
  • System shutdowns
  • Loss of Cisco TAC support

Always verify your chassis’s required airflow before ordering.


High Power for Demanding Workloads

With 1100W capacity, the PWR-C1-1100WAC-P supports:

  • High-density PoE++: Powering dozens of IP phones, Wi-Fi 6/6E/7 APs, cameras, and IoT devices
  • 40G/100G/400G optics and high-speed line cards
  • Modular uplinks and stacking in aggregation layers
  • Future-proofing for software and hardware upgrades

In redundant configurations, two 1100W PSUs provide ample headroom for peak loads while maintaining failover protection.

PWR-C1-1100WAC Specification

Power supply rated maximum 1100W
Total output BTU (Note: 1000 BTU/hr = 293W) 3793 BTU/hr, 1100W
Input-voltage range and frequency 115-240VAC,

50-60 Hz

Input current 12-6A
Output ratings -56V at 19.64A
Output holdup time 10 ms minimum at 102.5VAC
Power-supply input receptacles IEC 320-C16

(IEC60320-C16)

Power cord rating 13A
Physical specifications (H x W x D): 1.58 X 3.25 X 13.7 in
Operating temperature 23°F to 113°F (-5°C to 45°C)
Storage temperature -40°F to 158°F (-40°C to 70°C)
Relative humidity operating and nonoperating noncondensing 5 to 90% noncondensing
Altitude 10,000 ft. (3000 meters), up to 45°C
MTBF Calculated MTBF must be greater than 300,000 using Telcordia SR-332, Method 1, Case 3. Demonstrated MTBF is 500,000 hr (with 90% confidence level).
EMI and EMC compliance FCC Part 15 (CFR 47) Class A

ICES-003 Class A

EN 55022 Class A

CISPR 22 Class A

AS/NZS 3548 Class A

BSMI Class A (AC input models only)

VCCI Class A

EN 55024, EN300386, EN 50082-1, EN 61000-3-2, EN 61000-3-3

EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN 61000-6-1

Safety compliance UL 60950-1, CAN/CSA-C22.2 No. 60950-1, EN 60950-1, IEC 60950-1, CCC, CE Marking
LED indicators “AC OK”: Input power to the power supply is OK

“PS OK”: Output power from the power supply is OK

Brands

Cisco

Warranty

6 Month

Condition

New Pulled

Based on 0 reviews

0.00 Overall
0%
0%
0%
0%
0%
Be the first to review “AC Config 1 Power Supply 1100W PWR-C1-1100WAC-P”

Your email address will not be published. Required fields are marked *

Write a review

Reviews

There are no reviews yet.

My Cart
Close Wishlist
Close Recently Viewed
Categories